Multi-Channel Application Suite

The standard MAGNETOM C! configuration includes a complete range of Application Suites with clinically optimized examinations for all anatomic regions. Dedicated suites include Neuro, Angio, Cardiac, Body, Onco, Ortho and Pediatric Suite.

Features & Benefits

Features

  • 2D PACE (Prospective Acquisition CorrEction)
  • LOTA (Long Term Data Averaging) technique for motion and flow artifact reduction without increasing scan time
  • Elliptical scanning reduces scan time for 3D imaging
  • Selectable centric elliptical phase reordering via the user interface
  • Inversion Recovery to nullify the signal of fat, fluid or any other tissue
  • True Inversion Recovery to obtain strong T1-weighted contrast
  • Dark blood inversion recovery technique that nulls fluid blood signal
  • Saturation Recovery for 2D TurboFLASH, gradient echo, and T1-weighted 3D TurboFLASH with short scan time (e.g. MPRAGE)
  • Presaturation Technique. RF saturation pulses to suppress flow and motion artifacts. Up to six saturation bands may be positioned in any orientation
  • Tracking SAT Bands maintain constant saturation of venous and/ or arterial blood flow, e.g. for 2D/3D sequential MRA
  • Water Excitation. Spectral selective RF pulses for exclusive water excitation
  • Dixon for fat and water separation
  • RF Fat Saturation. Spectral selective RF pulses for saturation of fat
  • MTC (Magnetization Transfer Contrast). Off-resonance RF pulses to suppress signal from certain tissues, thus enhancing the contrast. Used e.g. in MRA
  • TONE (Tilted Optimized Non-saturating Excitation). Variable excitation flip angle to compensate inflow saturation effects in 3D MRA. TONE pulse selectable depending on
  • GMR (Gradient Motion Rephasing). Sequences with additional bipolar gradient pulses, permitting effective reduction of flow artifacts
  • Freely adjustable receiver bandwidth, permitting studies with increased signal-to-noise ratio
  • Freely adjustable flip angle. Optimized RF pulses for image contrast enhancement and increased signal-to-noise ratio
  • Simultaneous Excitation. Doubles the number of slices per TR for 2D GRE
  • Integrated Parallel Acquisition Technique (iPAT)
  • PAT averaging for motion artifact suppression using Self-Calibration
     

General Requirements

System

Other

This application is currently delivered as standard on most system configurations. Please contact your local sales representative for further information.

Please Note: Additional technical pre-requisites may apply. Upon receiving your request, your local Siemens representative will clarify whether your system meets the requirements.

Subscription Button Icon

Keep up to date on the latest trends in healthcare. Read about current developments, new products and upcoming events.